Time:2021-09-30

Please leave a message for us and we will reply in the first time

TES -60℃~200℃
Cooling Capacity:15kW~60kW
Dimension(cm):80*145*185~(185+60)*145*225
Support OEM customization!

PRODUCTS

  • 1 (1).jpg

    The device is used for fueling, lubricating oil cooling or heating when testing fuel, oil and the like for the test bench of Party A.

    The heat transfer oil refrigeration heating device provides low temperature or high temperature heat transfer oil, and the heat transfer oil and the fuel oil exchange heat in the inlet heat exchanger of the test piece, so that the fuel can reach the desired temperature condition.

    The secondary heat exchange completely solves the problem of temperature resistance of the fuel and oil delivery high pressure pump, and also solves the problem of fuel carbonization and coking caused by the excessive surface temperature of the heater.

    tes.png

    tes详情页图.jpg


    Our equipment supports all temperature heating and cooling functions related to chip manufacturing. Such as load test, etching and so on.


     ModelTES-6A15WPEXTES-6A15WDEXTES-6A25WPEXTES-6A25WDEXTES-6A45WPEXTES-6A45WDEXTES-6A60WPEXTES-6A60WDEX

    Temp Range-60℃~200℃
    Heating Power15kW~60kW
    Refrigerating Output200℃15kW~60kW

    100℃15kW~60kW

    20℃15kW~60kW

    0℃15kW~60kW

    -20℃12kW~48kW

    -40℃8kW~35kW

    -50℃5kW~25kW

    -55℃3kW~15kW
    Temp Control Accuracy Of Heat Conduction Medium±0.5℃
    Fuel Temp Control Accuracy±2℃ Steady State
    System Pressure DisplayPressure of Refrigeration system is realized by pressure gauge (High pressure, low pressure);

    Pressure of circulatory system is detected by pressure sensor and displayed on touch screen.
    ControllerSiemens PLC, Fuzzy PID Control algorithm with Cascade Control algorithm.
    Temperature ControlTemperature Control Mode for outlet of Heat conduction medium;

    External temperature sensor: (PT100 or 4~20mA or communication given) control mode (cascade control).
    Communicating ProtocolEthernet Interface TCP/IP Protocol
    Internal Temp FeedbackEquipment heat conduction medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, positive pressure chamber ambient temperature, compressor suction temperature, cooling water temperature (water-cooling equipment is configured).
    External Access Temp FeedbackPT100 or 4~20mA or communication given
    Cascade Control TimeThe temperature difference between the outlet temperature and the external temperature sensor can be set and controlled;
    TempDifference Control FunctionThe temperature difference between the inlet temperature and the outlet temperature of the equipment can be set to be controlled (to protect the safety of the system).
    Closed-cycle SystemThe whole system is a completely closed system with no oil mist at high temperature and no water in the air at low temperature. The system will not increase the pressure due to high temperature and automatically replenish the heat conduction medium at low temperature.
    HeatingThe maximum heating output power of the system (according to each model);

    The heater has triple protection and independent temperature limiter to ensure the safety of heating system;

    Heating power 10kW adopts regulator, heating power output control adopts 4~20mA linear control.
    Refrigerating CapacityRefers to the ability to take away heat at different temperatures (ideal condition), the actual working conditions need to consider environmental heat dissipation, please enlarge properly, and do a good job of insulation measures.
    High Temp Cooling ModuleFrom the high temperature 200 degrees cooling module.
    Circulating pump flow maxMagnetic drive pump with crown magnetic drive pump/ German brand.

    110L/min 2.5BAR200L/min 2.5BAR400L/min 2.5BAR500L/min 2.5BAR
    Source 380V 50HZ28kW max48kW max70kW max102kW max
    Shape Size (Positive Pressure)cm135 *145*225(135+60) *145*225(185+60) *145*225(185+60) *145*225
    External Dimension (Isolation)mm800*1450*18501000*1750*18501450*2050*20501450*2050*2050
    Compression EngineEmerson Scroll flexible compressor / BiZell /Carlyle
    EvaporatorDANFOSS / KAORI Plate Heat Exchanger
    Refrigeration AccessoryOil separator, dry filter, thermal expansion valve, electronic expansion valve, refrigeration solenoid valve, pressure control, mirror, etc. All adopt Emerson / Danvers brand.
    Operation PanelColor touch screen, temperature curve display EXCEL data export.
    Safe GuardingWith self-diagnosis function; phase sequence phase breaker, freezer overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions.
    CryogenR-404A R23 mixed refrigerant
    Interface SizeDN32 PN10 RFDN32 PN10 RFDN40 PN10 RFDN50 PN10 RF
    Water-Cooled WType W is water cooled.
    Water-cooled CondenserTube type heat exchanger(Pari's/Shenshi)
    Cooling Water Quantity At 32℃5m3/h8m3/h15m3/h20m3/h
    Shell materialCold rolled sheet spray (Standard Colour 7035)
    Barotropic Explosion ProtectionPositive pressure blast proof (EXPXdmbIICT4) barotropic system must be water-cooled equipment;

    Wuxi Guansub explosive proof product installation license number: PCEC-2017-B025
    Barotropic System CoolingA constant temperature cooling system is installed inside the barotropic system to ensure that the ambient temperature of the barotropic chamber is below 45℃
    NavarLNEYA
    Expansion SystemLNEYA
    Intermediate Relay Thermal RelayIntermediate relays, thermal relays, contactors, circuit breakers, etc., all use Schneider and other brands.
    Temperature SensorTiankang
    Explosion-proof HoseTu’an explosion-proof threading hose
    Internal&External ControlThis External control mode is switchable

    工厂实力 (2).jpg

    认证.jpg


    If you need this device, you can communicate with online customer service or leave a message in the form below.


  • tes.png


    oem12.jpg