Time:2021-09-30

Please leave a message for us and we will reply in the first time

AES -120℃~225℃
LNEYA is committed to solving the problem of temperature control lag in electronic components. Ultra high temperature cooling technology can be cooled directly from 300°C.

PRODUCTS

  • 射流_01.jpg

    Provides accurate and fast ambient temperature (-120 °C ~ +300 °C) for chips, modules, integrated circuit boards, and electronic components. It is an indispensable instrument for product electrical performance testing, failure analysis, and reliability assessment.

    Widely used in semiconductor companies, aerospace, optical communications, universities, research institutes and other fields.


    ModelAES-4535AES-6035AES-8035AES-A1035WAES-A1235W

    AES-4535WAES-6035WAES-8035W
    Temp. Range-45℃~225℃-60℃~225℃-80℃~225℃-100℃~225℃-120℃~225℃
    Heating Power3.5kW~4.5kW
    Refrigerating Output-45℃2.5kW

    -60℃2kW

    -80℃1.5kW

    -100℃1.2kW

    -120℃1.2kW
    Temp. Control Accuracy±1℃
    Temp. Conversion Time-25℃ to 150℃ Approximately 10S150℃ to  -25℃Approximately 20s-45℃ to 150℃ Approximately 10S150℃to  -45℃Approximately 20s-55℃ to 150℃ Approximately 10S150℃to  -55℃Approximately 15s-70℃ to 150℃ Approximately 10S150 ℃to  -70℃Approximately 20s-80℃ to 150℃ Approximately 11S150℃to  -80℃Approximately 20s


    Air RequirementAir Cleaner<5um

    Air Oil Content:<0.1ppm

    Air Temp&Humidity:5℃~32℃  0~50%RH
    Air Handing Capacity7m3/h ~ 25m3/h  Pressure 5bar~7.6bar
    System Pressure DispiayPressure of Refrigeration system is realized by pressure gauge (High pressure, low pressure);

    Pressure of circulatory system is detected by pressure sensor and displayed on touch screen.
    ControllerSiemens PLC, Fuzzy PID Control algorithm.
    Temp. ControlControl of outlet temperature
    Programmable10 procedures can be developed, and each program can be composed of 10 steps
    Communicating ProtocolEthernet Interface TCP/IP Protocol.
    Internal Temp. FeedbackEquipment outlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (water cooling equipment is configured) .
    Temp. FeedbackT Temperature Sensor
    Compression EngineTaikang,FranceItaly Duling
    EvaporimeterDouble-pipe (heat) Exchanger
    CalorifierFlanged Barrel Heater
    Refrigeration AccessoryDanfoss / Emerson fittings (dry filters, oil separators, high and low pressure protectors, expansion valves, solenoid valves).
    Operation PanelLNEYA custom 7-inch color touch screen, temperature curve display EXCEL data export.
    Safe GuardingWith self-diagnosis function; phase sequence phase breaker, freezer overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions.
    CryogenTopsubmixed Refrigerant
    External Insulation Hose8m DN32 fast coupling clamp for easy outgoing insulation hose
    Air-Cooled TypeCopper tube aluminum fin condensation mode, upper and out type, condensing fan using Germany EBM axial flow fan.
    Water-Cooled Type WType W is water cooled
    Water-Cooled CondenserSleeve type heat exchanger (Paris/ Shen's)
    Cooling Water Quantity At 25℃0.6m3/h~7m3/h
    Source 380V 50HZ4.5kW max
    SourceCustomizable 460V 60HZN 220V 60HZ three-phase
    Shell MaterialCold rolled sheet spray (Standard Colour 7035).
    Temp. SpreadHigh Temperature To +300℃



    If you need this device, you can communicate with online customer service or leave a message in the form below.

  • Compared to the traditional thermostat, there are several features:

    Temperature range: -120 °C ~ +300 °C;
    The temperature rise and fall is very fast, -55 °C ~ 150 °C < 10 seconds;
    Temperature control accuracy: ±1 °C;
    Temperature setting capability: ±0.1 °C;
    Temperature display capability: ±0.1 °C;
    Maximum air flow: 25m3/h;
    Real-time monitoring of the real temperature of the IC under test to achieve closed-loop feedback and adjust the gas temperature in real time;
    The temperature rise and fall time is controllable, programmable operation, manual operation and remote control.

    1_1617177442.jpg

    03.jpg

    03.jpg

    04.jpg