ultra low temperature equipment, pharmaceutical equipment, equipment modular controller          E-mail :  beckett@cnzlj.cn     alibaba facebook linkedin twitter

Wuxi Guanya Refrigertion Technoloy  Co., Ltd

Home > Products > Heating Circulator
  1. Heating Circulator
  2. Heating Circulator

Heating Circulator

  • DescriptionUC series with function of cooling down from high temperature and the temperature range from 300℃ to 50℃.
  • InformationHeating Circulator
  • Download

UC series with function of cooling down from high temperature and the temperature range from 300℃ to 50℃.

  1. Parameter
  2. Advantage
  3. Application

50℃~200℃Wuxi Guanya Refrigeration Technology  Co., Ltd

Technical Parameters:

Model

UC-A1520

UC-A2520

UC-A3820

UC-A6020

UC-A9520

UC-A13020

UC-A20020

Temperature range ℃

50℃~200℃

Controller

PID adaptive controller

Temp. Control optional

Heat-conducting medium outlet temp. control

Communication protocol

MODBUS RTU Protocol, RS 485 Interface

Temperature feedback

Heat-conducting medium temperature feedback PT100

Temp. accuracy

±0.5℃

±0.5℃

±1℃

±1℃

±1℃

±1℃

±2℃

Heating power

15kW

25kW

38kW

60kW

Divide to two

groups heating

95kW

Divide to three

groups heating

130kW

Divide to three

groups heating

200kW

Divide to four

groups heating

Heater can be divided into groups. When the testing temperature reached to (setting temperature -5℃),

it can close the most of heating duty and leave the next group to be PID fuzzy control.

Cooling

capacity

300℃

 

 

 

 

 

 

 

200℃

15kW

25kW

38kW

60kW

95kW

130kW

200kW

100℃

12kW

20kW

30kW

48kW

76kW

100kW

160kW

65℃

5kW

8.5kW

12kW

19kW

30kW

40kW

64kW

 

There is a heat exchanger in the system and it needs water to cool.

Open the water valve automatically according to demand.

Circulation pump

Max50L/min

2.5BAR

Max110L/min

2.5BAR

Max110L/min

2.5BAR

Max250L/min

2.5BAR

Max250L/min

2.5BAR

Max400L/min

2.5BAR

Max400L/min

2.5BAR

Expansion tank volume

35L

65L

90L

160L

240L

300L

500L

Heater

Orient electric heater

Independent temperature limiter

LNEYA

Cooler

Plate heat exchanger

Operation panel

Display setting temperature and testing temperature; Touch key display

Safety protection

Self-diagnosis function; freezer overload protection; high pressure switch, overload
relay, thermal protection device, liquid low level protection, high temperature
protection and temperature fault protection.

Closed circulation system

The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature,

pressure do not rise up when system is running. The system will supplement oil automatically at low temperature.

Connection size

DN-25

DN25

DN25

DN40

DN40

DN-50

DN-50

Dimension

600*600*1250

600*600*1250

1200*750*1100

1200*750*1100

1400*750*1300

1400*750*1300

1500*850*1450

Weight

100kg

130kg

170kg

285kg

318kg

450kg

685kg

Power

AC380V 50HZ

15.7kW (max)

AC380V 50HZ

26.5kW (max)

AC380V 50HZ

39.5k (max)

AC380V 50HZ

63kW (max)

AC380V 50HZ

98kW (max)

AC380V 50HZ

135.5kW (max)

AC380V 50HZ

206kW (max)

Case material

Cold rolled steel painting

Optional

Optional 7-inch color touch screen controller, temperature curve record, data export to excel format.

Optional

SUS 304    SUS 304 case material

Optional power

220V 60HZ three-phase, 440V~480V 60HZ three-phase

 

Model

UC-A1530

UC-A2530

UC-A3830

UC-A6030

Temperature range ℃

50℃~300℃

Controller

PID adaptive controller

Temp. Control optional

Heat-conducting medium outlet temp. control

Communication protocol

MODBUS RTU Protocol, RS 485 Interface

Temperature feedback

Heat-conducting medium temperature feedback PT100

Temp. accuracy

±0.5℃

±1℃

±1℃

±1℃

Heating power

15kW

25kW

38kW

60kW

Divide to two groups heating

Heater can be divided into groups. When the testing temperature reached to (setting temperature -5℃),

it can close the most of heating duty and leave the next group to be PID fuzzy control.

Cooling

capacity

300℃

15kW

25kW

38kW

60kW

200℃

13kW

22kW

32kW

50kW

100℃

10kW

17kW

27kW

40kW

65℃

4kW

6kW

11kW

16kW

 

There is a heat exchanger in the system and it needs water to cool.

Open the water valve automatically according to demand.

Circulation pump

Max50L/min

2.5BAR

Max110L/min

2.5BAR

Max110L/min

2.5BAR

Max250L/min

2.5BAR

Expansion tank volume

50L

80L

120L

220L

Heater

Orient electric heater

Independent temperature limiter

LNEYA

Cooler

Plate heat exchanger

Operation panel

Display setting temperature and testing temperature; Touch screen display

Safety protection

Self-diagnosis function; freezer overload protection; high pressure switch, overload
relay, thermal protection device, liquid low level protection, high temperature
protection and temperature fault protection.

Closed
circulation system

The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature,

pressure do not rise up when system is running. The system will supplement oil automatically at low temperature.

Connection size

DN-25

DN-25

DN-25

DN-40

Dimension

600*600*1250

600*600*1250

1200*750*1100

1200*750*1100

Weight

115kg

155kg

195kg

320kg

Power

AC380V 50HZ

16kW (max)

AC380V 50HZ

26.5kW (max)

AC380V 50HZ

39.5k (max)

AC380V 50HZ

63kW (max)

Case material

Cold rolled steel painting

Optional

Optional 7-inch color touch screen controller, temperature curve record, data export to excel format.

Optional

SUS 304    SUS 304 case material

Optional power

220V 60HZ three-phase, 440V~480V 60HZ three-phase


TAG:  Heating Circulator

Advantages:

  • Small space required

  • Low filling Volume

  • High Pump Capacity

  • Rapid & efficient filling of the complete

  • application with venting

  • +60 ℃ max. expansion tank temperature

  • Simple operation

  • High level of safety through constant

  • monitoring



TAG:  Heating Circulator

Description:

1. UC series with function of cooling down from high temperature and the temperature range from 300℃ to 50℃.
2. Equipped with heating and cooling system, large heat exchange area, rapid speed of heating-cooling, small demand of heat conducting medium.
3. Can heating-cooling continuously
4. The whole system is closed, there is no oil mist at high temperature, no volatilization of heat conducting medium at high temperature; With function of adjustable internal circulation PT100.  
5. The whole system is a closed liquid circulation system with expansion tank, the expansion tank and liquid circulation are thermal insulation, do not participate in liquid circulation, regardless of high or low temperature, the medium in expansion tank is limited to 60℃.


TAG:  Heating Circulator