ultra low temperature equipment, pharmaceutical equipment, equipment modular controller          E-mail :  beckett@cnzlj.cn     alibaba facebook linkedin twitter

Wuxi Guanya Refrigertion Technoloy  Co., Ltd

Home > Products > Low temperature circulator

    Low Temperature Circulator

    • DescriptionSaving resources;closed cycle pipeline design highly prevent circulating water pollution and extend the lifetime of circulation liquid.
    • InformationLow circulator, Low temp circulator, Constant temp circulator, Low circulator, Low temp circulation bath, Circulators bath, Circulation bath, Circulators, Chiller, Cooling circulators, Cooling bath circulators, Cooling thermostat, Refrigeration bath circulators, Refrigeration circulator, Refrigeration thermostats, Refrigeration bath circulator, Low temp freezer, Freezer, Low freezer, Low chiller, Freezer chiller, Cold trap, Immersion cooler, Low temp bath, Bath thermostats
    • Download

    Saving resources;closed cycle pipeline design highly prevent circulating water pollution and extend the lifetime of circulation liquid.

    1. Parameter
    2. Advantage
    3. Application
    Use high power equipment for industrial production,please refer to industrial production catalogue
    Description:

    1.Saving resources;closed cycle pipeline design highly prevent circulating water pollution and extend the lifetime of circulation liquid.
    2.Multi-safety protection,more reliable operation.
    3.Brand compressor,cascade refrigeration colling technologies.
    4.Human design,more convenient and flexible.
    5.Efficient two-condensate system.
    6.Computer-cascade temperature controller,temperature figures display,adjustable unit is 0.1℃,temperature range is 125℃~-20℃,PT100 temperature sensor.
    7.Use of cold technology,can guarantee the stability of temeprature at low temperature.
    8.Can set the temperature difference of compressor on/off.
    9.Monitoring the ambient temperature,prevent temperature to be higher in the running system.
    10.A variety of fault alarm (overtemperature alarm, sensor alarm, high pressure alarm, compressor overheat alarm, liquid level alarm).
    11.Power on delay protection,three-level cascade system protectors.
    12.All parts are safety grounding.
    13.Adopt full closed circulation design,no water vapor at low temperature and ensure the purity of cooling medium,in case of ice crystals,provide a long timelife of heat transfer liquid.
    14.High-performance circulating pump, can guarantee 24 hours continuously running a day.
    15.Use plate cool-heat-exchanger,heat transfer efficiency is provided.

    Powered by MetInfo 5.3.18 ©2008-2018 www.metinfo.cn